Today's progressed ultrasonic stream meters empower the
faultless estimation of fluid stream over a wide assortment of methodology
control, water asset administration, and vigor utilization requisitions. To
select the right ultrasonic flowmeter for your particular fluid requisition,
you should first comprehend the four essential courses in which ultrasonic
flowmeters are characterized:
Estimation standard: Transit-time vs. Doppler
Travel time flowmeters are dependent upon the time
distinction between upstream and downstream sound spread interims, and give a
standout amongst the most dependable and time tried estimation standards
accessible to date. This approach gives extremely great precision (±1-2%), and
works well for clean stream requisitions or stream with minor particles.
Requisitions incorporate immaculate water, ocean water, wash water, sewage,
process fluids, oils, chemicals, and anyâ homogeneous fluids which are equipped
for ultrasonic wave spread.
Doppler Flödesmätare
is dependent upon the Doppler Effect. They work well with suspension streams
where molecule fixation is above 100ppm and molecule size is bigger than 100um,
yet less than 15% in focus. Doppler is less demanding to make and less precise
(±5%), accordingly, it is shabbier than a travel time flowmeter.
Unit Portability: Handheld vs. Divider mount
Handheld (or versatile) flowmeters are adequate for stream
overview, Hvac, and different provisions where versatility is a discriminating
necessity. Some handheld flowmeters could be sent as enduring estimation
results when and if nature is pleasing.
Divider mount (or altered establishment) flowmeters are more
suitable for requisitions, for example handle control and enduring persistent
stream checking. The instrument walled in area is regularly climate safe or
blast proof. These sorts of meters are typically shabbier than handheld
mechanisms since they are ordinarily requested in expansive amounts.
Transducer establishment: Clamp-on vs. Wetted
Brace on flowmeters are non-meddling, simple to instate and
simple to uphold. The transducers are mounted outside of a channel and donate
require the cutting or penetrating of the genuine funnel. Cinch on transducers
are nonintrusive and along these lines make no contamination or force drop in
the fluid being measured.
There are two mixtures of wetted flowmeters, insertion and
stream cell (inline sort). Insertion flowmeters require the funnels to be bored
to instate the transducers. Be that as it may, various makers give hot-tapping
devices which take into consideration the transducer establishment without depressurizing
the funnel or closing down the stream.
Stream cell, likewise called spool piece are instituted in
accordance with the channel, through the utilization of uncommon funnel
fittings. The transducers are preinstalled on the stream cell, along these
lines, establishment failures are kept to a base. By and large, wetted
transducers furnish better exactness and enduring dependability over clasp on
mixed bags, however generally take more.
Transducer plan: Single-way vs. Multi-Path
Single-way flowmeters use one set of transducers to shape
one ultrasonic way to capture the stream in a funnel. It is suitable for minor
and medium measure funnels. For bigger pipe sizes, shorter straight funnel runs
and more stupendous correctness, multi-way transducer establishment is an
exceptional choice.